偏摆仪的使用说明
时间:2016/2/27 15:01:49
浏览量:1252
1、产品概述
本产品主要用于检测轴类,盘类别件的径向园跳动和端面园跳动。
2、技术数据
(1)5030型:
两顶尖最大距离:500㎜,顶尖中心高度:300㎜,另外最大直径:560㎜。
精度:两顶尖连线对仪座导轨面的平行度,顶尖中心线在100㎜范围内对导轨的平行度。
顶尖距500 顶尖距100
水平方向≤0.003 ≤0.003 ≤0.001
垂直方向≤0.003 ≤0.003 ≤0.001
顶尖60°锥面对莫氏锥的径向跳动≤0.005。
(2)10030型:
两顶尖最大距离:1000㎜,顶尖中心高度:300㎜,另外最大直径:560㎜。
精度:两顶尖连线对仪座导轨面的平行度,顶尖中心线在100㎜范围内对导轨的平行度。
顶尖距1000 顶尖距500 顶尖距100
水平方向≤0.05 ≤0.07 ≤0.002 ≤0.003
垂直方向≤0.03 ≤0.02 ≤0.01 ≤0.003
顶尖60°锥面对莫氏锥的径向跳动≤0.005。
3、使用方法
拧紧偏心轴手把,首先将固定顶尖座在仪座上固定。按被测另件长度将活动顶尖座固定在合适位置。压下球头手柄,装入另件用两顶尖顶住另件中心孔。拧紧紧定手把将顶尖固定。移动支架座至所需位置然后固定它,通过其上所装的面分表(千分表)即可进行检测工作。
4、维护保养
(1)仪器使用及放置的场地应通风干燥,不宜过分潮湿。
(2)保管及使用过程中严禁撞击划伤。
(3)顶尖、仪座导轨等重要另件和部位使用后应用汽油洗净并涂上防锈油,不得锈蚀。仪器滑动部分要经给以润滑,但油层不易过厚,以免影响仪器示值精度,没标应经常注入润滑油。
(4)仪器使用完毕后,应用防尘罩罩好,以免尘土落到导轨及有关表面上,以保证仪器使用精度。
1. Product overview
This product is mainly used to detect radial circular and
end circular runout of shaft and disk parts.
2. Technical data
(1) Type 5030:
The maximum distance between the two apices is 500 feet,
the center height of the apex is 300 feet, and the maximum diameter is 560
feet.
Accuracy: The parallelism of the two apex lines to the
guide surface of the instrument base and the parallelism of the apex center
line to the guide rail in the range of 100.
Top Distance 500 Top Distance 100
Horizontal direction < 0.003 < 0.003 < 0.001
Vertical direction < 0.003 < 0.003 < 0.001
The radial runout of the top 60 degree cone is less than
0.005.
(2) Type 10030:
Maximum distance between two apices: 1000 feet, apex
center height: 300 feet, and maximum diameter: 560 feet.
Accuracy: The parallelism of the two apex lines to the
guide surface of the instrument base and the parallelism of the apex center
line to the guide rail in the range of 100.
Top Distance 1000 Top Distance 500 Top Distance 100
Horizontal direction < 0.05 < 0.07 < 0.002 <
0.003
Vertical direction < 0.03 < 0.02 < 0.01 <
0.003
The radial runout of the top 60 degree cone is less than
0.005.
3. Usage
Tighten the eccentric shaft handle, and fix the fixed
apex seat on the instrument seat first. The movable top seat is fixed in the
proper position according to the length of the other part under test. Press
down the ball handle and load the other piece into the center hole of the other
piece with two pins. Tighten the handle tightly to fix the top. Moving the
bracket to the desired position and fixing it, the detection can be carried out
through the surface meter (micrometer) mounted on it.
4. Maintenance
(1) The site where the instrument is used and placed
should be ventilated and dry, and should not be excessively humid.
(2) Collision and scratch are strictly prohibited during
storage and use.
(3) Use gasoline to wash and coat rust-proof oil on the
top, seat guide rail and other important parts after use, so as not to rust.
The sliding part of the instrument should be lubricated, but the oil layer is
not too thick, so as to avoid affecting the accuracy of the instrument
indication. Lubricating oil should be injected frequently without standard.
(4) After the instrument has been used, the dust-proof
cover should be applied to prevent dust from falling on the guide rail and
related surface, so as to ensure the accuracy of the instrument.
Company
name: botou zhuoyuan mechanical equipment manufacturing co.,LTD
Registered address: jiaohe development zone, botou
city, hebei province
Fax number: 0317-8031093
Contact information: 15369812793 (WeChat with the same
number) liansheng chu
Postcode: 062151
Enterprise email:1358827475@qq.com
Account Opening Bank: Botou Branch of Bank of China
Account number: 100399943203
Agricultural bank account number: 6228481739059615270
http://zhuoyuanjixie.com